EC
Klarstein Refrigerant System / Low Refrigerant Protection

Klarstein AC shows EC and stops cooling; may attempt to restart and fail.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Low refrigerant charge due to leak, blocked capillary or expansion device, faulty pressure sensor, defective main PCB interpreting sensor data

How to Fix / Troubleshooting

Safety: Refrigerant circuits are sealed and under pressure. Only licensed technicians should connect gauges or open the system.

User checks:

  • Airflow: Ensure both indoor and outdoor coils and filters are clean and fans are operating.
  • Operating conditions: Confirm doors and windows are closed and the space is within the unit’s capacity.

Technician checks:

  • Pressure test: Connect gauges to verify system pressures and confirm low charge or blockage.
  • Leak detection: Use electronic leak detector or dye to locate leaks. Repair leaks and evacuate/recharge with the correct refrigerant type and weight specified by Klarstein.
  • Sensor/PCB: Test the pressure sensor and replace if faulty. If sensor is good, the main PCB may need replacement.

Do not attempt to add refrigerant yourself; improper charging can damage the compressor and void warranty.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Refrigerant Pressure Sensor
Check Price on Amazon