F5
Klarstein Outdoor Ambient Temperature Sensor Error

Klarstein AC shows F5 and may stop cooling or heating (for heat pump models).

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective outdoor ambient NTC sensor, sensor exposed to direct sun or heat source, wiring damage, outdoor PCB fault

How to Fix / Troubleshooting

Safety: Turn off power before accessing the outdoor unit.

Steps:

  • Locate sensor: The outdoor ambient sensor is usually mounted near the outdoor coil or on the chassis, away from direct coil heat.
  • Check placement: Ensure it is not touching hot discharge pipes or in direct sunlight. Reposition if necessary.
  • Inspect wiring: Look for damage or corrosion at the connector. Clean and reseat.
  • Test sensor: Measure resistance and compare to expected NTC values. Replace if faulty.

If F5 persists, the outdoor PCB’s sensor circuit may be defective and require replacement.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Outdoor Ambient NTC Sensor
Check Price on Amazon

We may earn a commission from links on this page.