H3
Klarstein
Compressor Overload Protection / Overcurrent
Klarstein AC stops with H3 code; compressor does not restart.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked condenser, failed condenser fan, incorrect supply voltage, failing compressor, main PCB current sensing fault
How to Fix / Troubleshooting
Safety: High-voltage and compressor circuits are involved. Unplug or isolate power before inspection.
Steps:
- Airflow and cleaning: Clean condenser coil and ensure fan operation as described for E8.
- Voltage check: Verify mains voltage is within specification. Persistent low or high voltage can trigger H3.
- Fan and capacitor: Confirm condenser fan runs at full speed; test and replace fan capacitor if needed.
- Compressor health: If the compressor is extremely hot to touch and frequently trips, it may be failing internally and must be evaluated by a refrigeration technician.
H3 that recurs after airflow and electrical checks usually indicates a compressor or PCB issue requiring professional service.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Compressor Assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements