Klarstein air conditioner blows warm air in cooling mode.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety: Unplug before internal inspection; refrigerant work must be done by a professional.
Steps:
- Verify mode: Confirm the unit is set to Cool mode and not Heat or Fan.
- Check compressor: Listen for compressor operation. If only the fan runs, see the "Compressor Not Starting" scenario.
- Clean coils: Clean both indoor and outdoor coils and ensure fans are running.
- Heat pump valve: On heat pump models, if the unit heats when set to cool, the four-way valve may be stuck. This requires a technician to diagnose and possibly replace the valve or coil.
If airflow is good and compressor runs but air remains warm, the refrigerant charge is likely incorrect and must be checked by a licensed technician.
Repair Difficulty
Required Part
We may earn a commission from links on this page.