Klarstein Indoor Fan Failure

Klarstein air conditioner outdoor unit runs but indoor fan does not blow air.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed indoor fan motor, faulty fan capacitor, loose fan connector, blocked blower wheel, defective indoor PCB fan driver

How to Fix / Troubleshooting

Safety: Unplug the indoor unit before opening the casing.

Steps:

  • Check for obstructions: Remove the front cover and inspect the blower wheel for obstructions or ice.
  • Spin test: Try turning the blower by hand. If stiff, the motor bearings may be seized.
  • Capacitor (if used): Locate and test the indoor fan capacitor. Replace if out of spec.
  • Motor replacement: If the motor does not run with correct voltage and a good capacitor, replace the indoor fan motor assembly.

If a new motor does not resolve the issue, the indoor PCB fan driver is likely faulty and must be replaced.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Indoor Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements