E5
Klimaire
Overcurrent Protection / Compressor Overload
Indoor unit shows E5 and the system shuts down shortly after starting.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Shorted or locked compressor, Failing compressor run capacitor (on non-inverter models), Short circuit in outdoor wiring or terminals, Blocked condenser coil causing high amp draw
How to Fix / Troubleshooting
Safety first: This fault involves high voltage and high current. Turn OFF all power and use extreme caution. Many Klimaire units are inverter-driven; only qualified personnel should test compressor circuits.
- Step 1 – Visual inspection: Check outdoor wiring for burnt insulation, loose connections, or signs of arcing at the terminal block.
- Step 2 – Clean condenser coil: Ensure the outdoor coil is clean and unobstructed to reduce compressor load.
- Step 3 – Check fan operation: Confirm the outdoor fan runs whenever the compressor is commanded on. A non-running fan can cause rapid overcurrent.
- Step 4 – Capacitor check (non-inverter only): If your Klimaire model uses a start/run capacitor, have it tested and replaced if out of spec.
- Step 5 – Professional compressor/board diagnosis: If E5 persists, a technician should measure compressor winding resistance, insulation, and current draw, and verify the outdoor inverter PCB is not shorted.