E7
Klimaire Reversing Valve / Mode Conflict Fault

Indoor unit shows E7 and the system may not switch between cooling and heating properly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective reversing valve coil, Loose connection to reversing valve coil, Faulty outdoor PCB control of reversing valve, Stuck reversing valve slide

How to Fix / Troubleshooting

Safety first: Turn OFF power at the outdoor disconnect before accessing the outdoor unit.

  • Step 1 – Listen for valve change: When switching between COOL and HEAT, listen at the outdoor unit for a distinct whooshing sound indicating the reversing valve is shifting. Absence of this sound may indicate a stuck valve or no coil energization.
  • Step 2 – Inspect coil wiring: Locate the reversing valve solenoid coil on the outdoor unit. Check that its wires are firmly connected and not damaged.
  • Step 3 – Coil resistance check (pro): Using a multimeter, measure the coil resistance and compare with Klimaire specifications. Replace the coil if open or shorted.
  • Step 4 – PCB output check (pro): A technician should verify that the outdoor PCB is sending the correct voltage to the coil when changing modes.
  • Step 5 – Valve replacement (pro only): If the coil and PCB are good but the valve is stuck internally, the reversing valve must be replaced by a licensed HVAC technician, as this requires refrigerant recovery and brazing.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Reversing Valve Coil or Reversing Valve Assembly