F2
Klimaire Indoor Evaporator Coil Temperature Sensor (T2) Fault

Indoor unit displays F2 and may shut down or operate erratically.

Advertisements

Possible Causes

Open or shorted evaporator sensor, Sensor not properly attached to coil, Damaged sensor harness, Faulty indoor PCB sensor input

How to Fix / Troubleshooting

Safety first: Disconnect power before working near the evaporator coil.

  • Step 1 – Access sensor: Remove the front panel and filters. The T2 sensor is clipped directly to the evaporator coil tubing.
  • Step 2 – Check attachment: Ensure the sensor is firmly clipped to the coil and making good thermal contact. Re-clip if loose.
  • Step 3 – Inspect wiring and connector: Trace the sensor wires to the PCB and reseat the connector. Look for nicks or crushed insulation.
  • Step 4 – Replace sensor: If the error remains, install a new Klimaire T2 sensor. If a new sensor does not resolve the issue, the indoor PCB may be defective.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Indoor Evaporator Temperature Sensor (T2)
Check Price on Amazon

We may earn a commission from links on this page.