F3
Klimaire
Outdoor Ambient Temperature Sensor (T3) Fault
Indoor unit shows F3 and may stop heating or cooling.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Open or shorted outdoor ambient sensor, Sensor exposed to direct sunlight or non-ambient conditions, Damaged sensor wiring, Faulty outdoor PCB sensor circuit
How to Fix / Troubleshooting
Safety first: Turn OFF power at the outdoor disconnect before opening the outdoor unit.
- Step 1 – Locate sensor: The T3 sensor is usually mounted near the outdoor air intake, away from direct discharge air.
- Step 2 – Inspect mounting: Ensure the sensor is properly positioned to sense true outdoor air temperature, not touching hot components.
- Step 3 – Check wiring: Follow the sensor leads to the outdoor PCB. Reseat the connector and inspect for damage.
- Step 4 – Replace sensor: If F3 persists, replace the outdoor ambient sensor with a Klimaire-approved part.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Outdoor Ambient Temperature Sensor (T3)
Check Price on Amazon
We may earn a commission from links on this page.