F4
Klimaire Outdoor Condenser Coil Temperature Sensor (T4) Fault

Indoor unit displays F4 and the system may shut down, especially in heating mode.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open or shorted outdoor coil sensor, Sensor not properly attached to condenser coil, Damaged sensor harness, Defective outdoor PCB sensor input

How to Fix / Troubleshooting

Safety first: Disconnect power before accessing the outdoor coil area.

  • Step 1 – Access sensor: Remove the outdoor unit side panel. Locate the sensor clipped to the condenser coil tubing.
  • Step 2 – Verify attachment: Ensure the sensor is firmly clipped and in good contact with the coil. Re-secure if loose.
  • Step 3 – Inspect wiring: Check the sensor cable for cuts or abrasions. Reseat the connector on the outdoor PCB.
  • Step 4 – Replace sensor: Install a new Klimaire T4 sensor if the error remains. If a new sensor does not fix it, the outdoor PCB may need replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Outdoor Condenser Coil Temperature Sensor (T4)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements