F4
Klimaire
Outdoor Condenser Coil Temperature Sensor (T4) Fault
Indoor unit displays F4 and the system may shut down, especially in heating mode.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Open or shorted outdoor coil sensor, Sensor not properly attached to condenser coil, Damaged sensor harness, Defective outdoor PCB sensor input
How to Fix / Troubleshooting
Safety first: Disconnect power before accessing the outdoor coil area.
- Step 1 – Access sensor: Remove the outdoor unit side panel. Locate the sensor clipped to the condenser coil tubing.
- Step 2 – Verify attachment: Ensure the sensor is firmly clipped and in good contact with the coil. Re-secure if loose.
- Step 3 – Inspect wiring: Check the sensor cable for cuts or abrasions. Reseat the connector on the outdoor PCB.
- Step 4 – Replace sensor: Install a new Klimaire T4 sensor if the error remains. If a new sensor does not fix it, the outdoor PCB may need replacement.