P4
Klimaire Inverter Module Overheat / IPM Temperature Protection

Indoor unit shows P4 and the system may not operate.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked airflow around outdoor unit, Dirty heat sink on inverter module, Failed inverter cooling fan (if equipped), Degraded thermal paste between IPM and heat sink

How to Fix / Troubleshooting

Safety first: Disconnect power before opening the outdoor unit.

  • Step 1 – Ensure ventilation: Confirm the outdoor unit has adequate clearance and is not enclosed.
  • Step 2 – Clean heat sink area: Remove the outdoor PCB cover and gently blow out dust from the inverter heat sink and surrounding area.
  • Step 3 – Check any auxiliary fans: If your model uses a dedicated electronics cooling fan, verify it operates when the compressor runs.
  • Step 4 – Professional service: If P4 recurs, a technician may need to reapply thermal compound or replace the inverter board.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Outdoor Inverter Power Board / Heat Sink Assembly