Klimaire Outdoor Fan Failure

Outdoor fan does not run while compressor is operating; outdoor unit becomes very hot.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed outdoor fan motor, Faulty fan capacitor (on PSC motors), Loose wiring to fan motor, Defective outdoor PCB fan relay or driver

How to Fix / Troubleshooting

Safety first: Turn OFF power at the disconnect before touching the outdoor unit.

  • Step 1 – Visual check: Confirm the compressor is running (vibration and sound) while the fan is stationary.
  • Step 2 – Inspect wiring: Check the fan motor wires and connectors for burns or looseness.
  • Step 3 – Capacitor test (if equipped): On non-inverter models with a separate fan capacitor, have it tested and replace if out of spec.
  • Step 4 – Motor replacement: If the motor hums but will not start, or has seized bearings, replace the outdoor fan motor with the correct Klimaire part.
  • Step 5 – PCB check: If the motor and capacitor are good, a technician should test the outdoor PCB fan output.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Outdoor Condenser Fan Motor
Check Price on Amazon