Possible Causes
Weak compressor start relay, low supply voltage, failing main control board relay, seized compressor
How to Fix / Troubleshooting
Safety first: Unplug the unit. High voltage is present on the control board and compressor terminals.
Steps:
- 1. Verify voltage: Have a qualified person check that the outlet voltage matches the unit’s rating and is not sagging under load.
- 2. Inspect control board: Remove the control box cover and listen/feel for relays clicking repeatedly when cooling is commanded.
- 3. Check start relay: Inspect the compressor start relay/PTC for signs of overheating or cracking. Replace if suspect.
- 4. Board replacement: If the relay on the board is chattering and the compressor and start components test good, the main control board may need replacement.
- 5. Technician check: A seized compressor will cause repeated start attempts and relay chatter; a technician must confirm and advise on replacement.