Koldfront Relay Chatter / Start Circuit Problem

Clicking or buzzing noise from the control area when the compressor should start, but compressor does not run.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Weak compressor start relay, low supply voltage, failing main control board relay, seized compressor

How to Fix / Troubleshooting

Safety first: Unplug the unit. High voltage is present on the control board and compressor terminals.

Steps:

  • 1. Verify voltage: Have a qualified person check that the outlet voltage matches the unit’s rating and is not sagging under load.
  • 2. Inspect control board: Remove the control box cover and listen/feel for relays clicking repeatedly when cooling is commanded.
  • 3. Check start relay: Inspect the compressor start relay/PTC for signs of overheating or cracking. Replace if suspect.
  • 4. Board replacement: If the relay on the board is chattering and the compressor and start components test good, the main control board may need replacement.
  • 5. Technician check: A seized compressor will cause repeated start attempts and relay chatter; a technician must confirm and advise on replacement.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Main Control Board or Compressor Start Relay
Check Price on Amazon

We may earn a commission from links on this page.