E8
Koldfront High Temperature / Overheating Protection Fault

Display shows E8 and unit may shut down or run at reduced capacity.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked condenser airflow, dirty condenser coil, failed condenser fan motor, high ambient temperature beyond design, restricted return air

How to Fix / Troubleshooting

Safety first: Unplug the unit before cleaning coils or accessing the fan. Do not operate the unit with covers removed.

Steps to resolve E8:

  • 1. Improve ventilation: Ensure the outdoor side of the Koldfront unit has adequate clearance and is not enclosed by covers, screens, or tight spaces.
  • 2. Clean condenser coil: Access the outdoor coil and gently brush off dirt and debris. For heavy buildup, use a non-corrosive coil cleaner and rinse carefully, keeping water away from electrical components.
  • 3. Check condenser fan: With power disconnected, spin the outdoor fan blade by hand. It should move freely without grinding. If stiff or noisy, the fan motor may be failing.
  • 4. Inspect fan motor wiring: Verify that the condenser fan motor wires are intact and firmly connected to the control board or capacitor (if used).
  • 5. Reduce load: On extremely hot days, set the thermostat a few degrees higher and use additional fans indoors to reduce strain on the unit.
  • 6. Technician service: If E8 persists after cleaning and verifying fan operation, a technician should check refrigerant pressures and the high-pressure protection circuit.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Condenser Fan Motor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements