H3
Koldfront Compressor Overload / High Temperature Protection

On heat-capable models, display shows H3 and unit stops heating or cooling.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked condenser coil, failed condenser fan motor, low refrigerant causing overheating, compressor internal fault

How to Fix / Troubleshooting

Safety first: Unplug the unit. Compressor and high-pressure issues can be hazardous.

Steps to respond to H3:

  • 1. Allow cooling: Let the unit sit powered off for at least 30 minutes to allow the compressor to cool and internal overload to reset.
  • 2. Clean condenser: Inspect and clean the outdoor coil and grille to ensure proper airflow.
  • 3. Check condenser fan: Verify the outdoor fan runs whenever the compressor is on. If the fan is not running or is slow, the fan motor or capacitor (if used) may be faulty.
  • 4. Reduce load: Avoid setting the thermostat to extreme temperatures; use moderate setpoints.
  • 5. Professional service: If H3 recurs, a technician should check refrigerant charge, compressor current draw, and high-pressure switch operation.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Condenser Fan Motor or Compressor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements