Compressor Start Failure
Unit turns on but compressor does not start; only the fan runs and no cooling occurs.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed compressor, faulty start relay or PTC, bad run capacitor (if used), loose compressor wiring
How to Fix / Troubleshooting
Safety first: Unplug the unit. Compressor circuits carry high voltage and can be dangerous.
Steps:
- 1. Listen for sounds: When cooling is selected, listen for a click and a deeper humming sound from the compressor. A brief hum followed by a click may indicate a locked compressor or bad start device.
- 2. Check airflow and settings: Confirm the unit is set to Cool mode with a low enough temperature setpoint and that the fan is running.
- 3. Access compressor compartment: Remove the outer shell (window/through-the-wall) or rear panel (portable) to access the compressor area.
- 4. Inspect wiring: Verify that all wires to the compressor terminals, start relay/PTC, and capacitor are firmly connected and not burnt.
- 5. Replace start components: If the start relay or capacitor is visibly damaged or tests bad with a meter, replace with Koldfront-specified parts.
- 6. Professional diagnosis: If the compressor still will not start, a technician must check compressor windings and system pressures. Compressor replacement is not a DIY repair.