E450
Lennox Condensate Overflow Protection Trip

Lennox system shows E450 condensate overflow or float switch error; cooling is disabled even though thermostat is calling.

Advertisements

Possible Causes

Clogged primary condensate drain, Full auxiliary drain pan, Stuck or failed float switch, Improper drain trap causing backup

How to Fix / Troubleshooting

Safety: Turn off power to the indoor unit. Water around electrical components is hazardous.

  • 1. Inspect drain pan: Remove the blower/coil access panel and check the primary and secondary drain pans for standing water. Use a wet/dry vacuum to remove water if present.
  • 2. Clear condensate drain line: At the outside termination or cleanout, use a wet/dry vacuum to suck out debris and algae. Flush the line with a mixture of water and a small amount of vinegar or approved condensate cleaner.
  • 3. Check float switch: Locate the float switch on the pan or drain line. Manually lift and release the float to ensure it moves freely and clicks. Replace if stuck or corroded.
  • 4. Verify trap and slope: Ensure the drain line has a proper trap (for negative pressure systems) and slopes continuously downward to the outlet.

Note: Do not bypass the float switch; it protects your home from water damage.