E470
Lennox Compressor Overheating / Overload Trip

Lennox system reports E470 compressor overload or thermal protection trip; compressor shuts off and may restart after cooling down.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Dirty condenser coil, Low refrigerant charge causing high superheat, Failing condenser fan motor, Non-condensables or restriction in refrigerant circuit

How to Fix / Troubleshooting

Safety: Turn off power at the outdoor disconnect before cleaning or inspecting the unit.

  • 1. Clean condenser coil: Remove debris and wash the coil from inside out with a garden hose. Allow to dry before restoring power.
  • 2. Verify fan operation: Restore power and observe that the condenser fan starts and runs at full speed whenever the compressor runs. Replace the fan motor or capacitor if it fails to start or runs slowly.
  • 3. Shade and airflow: Ensure the unit has adequate clearance and is not in a confined, overheated space. Improve shading if the unit is in direct afternoon sun, but do not block airflow.
  • 4. Call for refrigerant diagnostics: If overload trips continue, a technician must check refrigerant charge, superheat/subcooling, and look for restrictions or non-condensables.

Warning: Repeated overload trips can permanently damage the compressor windings.