Possible Causes

Dirty air filter, Closed or blocked supply/return vents, Low blower speed, Low refrigerant charge or TXV issue

How to Fix / Troubleshooting

Safety: Turn off cooling and set fan to ON to thaw the coil. Do not chip ice.

  • 1. Replace filter and open vents: Ensure unrestricted airflow through the Lennox air handler.
  • 2. Inspect coil after thawing: Clean any dirt or debris from the coil surface.
  • 3. Verify blower speed settings: On PSC systems, confirm the cooling speed tap is on the correct terminal. On ECM systems, a technician can adjust airflow settings.
  • 4. Schedule refrigerant check: If freeze-ups continue, a technician must check for low charge or TXV malfunction.

Note: Repeated freeze-ups can cause water damage and compressor stress.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Lennox TXV (Thermostatic Expansion Valve)