Lennox Thermostat Power Loss

Lennox air conditioner thermostat display is blank or unresponsive; system does not run.

Advertisements

Possible Causes

Blown low-voltage fuse on indoor board, Broken R or C wire, Tripped float switch opening R circuit, Failed thermostat

How to Fix / Troubleshooting

Safety: Turn off power to the indoor unit before accessing the control board.

  • 1. Check thermostat batteries: Replace batteries if your Lennox thermostat uses them.
  • 2. Inspect low-voltage fuse: Replace the 3–5A fuse on the control board if blown.
  • 3. Verify R and C connections: Ensure the R and C wires are firmly connected at both thermostat and control board.
  • 4. Check float switch: A tripped condensate float switch may cut power to R. Clear the drain and reset the switch.

Note: If the thermostat remains blank with proper wiring and fuse, it may need replacement.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Lennox Thermostat
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements