Lennox Outdoor Unit Power or Contactor Failure

Outdoor Lennox air conditioner unit will not turn on at all; indoor blower runs and thermostat appears normal but condenser is silent.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Tripped outdoor disconnect, Tripped breaker feeding condenser, Failed contactor coil, Broken low-voltage wire to outdoor unit

How to Fix / Troubleshooting

Safety: Use extreme caution around high voltage. Turn off the breaker before opening the outdoor unit.

  • 1. Check breaker and disconnect: Verify the AC breaker in the panel is ON. At the outdoor disconnect, ensure the pull-out or switch is fully inserted/on.
  • 2. Listen for contactor click: With thermostat calling for cooling, stand near the condenser. If you do not hear a click, the contactor may not be energizing.
  • 3. Inspect low-voltage wires: Remove the control panel cover and check the small thermostat wires on the contactor coil. Tighten loose connections and repair any damaged cable.
  • 4. Replace contactor if coil is open: With power off, a technician can test the contactor coil resistance. If open, replace with the correct Lennox contactor.

Note: If the breaker trips immediately when reset, do not keep resetting; call a professional to locate the short.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Lennox Contactor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements