CH04
LG Drain Pump or Drain Level Sensor Fault (Indoor Unit)

Indoor display shows CH04 and the unit may not start or may shut down shortly after starting.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed internal condensate drain pump, Blocked drain line causing high water level, Faulty float/level sensor in drain pan, Loose or damaged wiring between pump/sensor and indoor PCB

How to Fix / Troubleshooting

Safety: Turn off power at the breaker before opening the indoor unit. Water and electricity together are hazardous.

Steps to address CH04:

  • Check for water overflow: Remove the front cover and inspect the drain pan. If it is full of water, do not run the unit until the cause is found.
  • Clear the drain line: Locate the condensate drain hose. Use a wet/dry vacuum at the hose outlet or gently blow compressed air from the indoor side to clear clogs (algae, sludge, debris).
  • Inspect the drain pump (if equipped): Some LG indoor units have an internal pump. Check for kinks in the pump discharge line and ensure the pump is not jammed with debris.
  • Check float/level sensor: Locate the float switch or water level sensor in the drain pan. Make sure it moves freely and is not stuck in the "high" position. Clean any slime or buildup.
  • Verify wiring: Confirm that the pump and sensor connectors are firmly seated on the indoor PCB and that no wires are cut or corroded.
  • Test operation: With covers still off but all wiring reconnected, briefly restore power and run the unit while observing the pump. Ensure it activates and removes water, then turn power back off.
  • Replace components if needed: If the pump does not run or the float sensor does not change state when moved, replace the faulty LG drain pump or float/level sensor assembly.
  • Reassemble: After confirming proper drainage, reassemble the unit and test for normal operation without CH04.

Call a technician if: The pump and sensor are functional but CH04 persists, as the indoor PCB or firmware may be defective.