H1
Luxaire Defrost Sensor / Defrost Mode Indication

Luxaire heat pump (AC mode capable) shows H1; unit may go into defrost or stop cooling temporarily.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Outdoor coil temperature sensor reading low, Normal defrost operation (in heat mode), Sensor misplacement on coil

How to Fix / Troubleshooting

Note: On Luxaire heat pumps, H1 can indicate defrost operation and may not be a fault if occurring in heating mode.

  • Confirm operating mode: If the system is in HEAT and outdoor conditions are cold, brief H1 indications can be normal.
  • Check coil sensor: If H1 appears in cooling mode or excessively, inspect the outdoor coil sensor for proper placement and secure attachment to the coil.
  • Replace faulty sensor: If the sensor is damaged, replace it with the correct Luxaire coil thermistor.
  • Call technician if frequent: Repeated or prolonged H1 in cooling mode may indicate control board or sensor calibration issues requiring professional service.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Outdoor Coil Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.