L2
Luxaire
Low Voltage on Control Circuit (24V)
Luxaire AC shows L2; system may intermittently shut down, especially during compressor start.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Weak transformer, Short in thermostat wiring, Loose low‑voltage connections, Faulty float switch in condensate line
How to Fix / Troubleshooting
Safety: Turn off power to the air handler before working on low‑voltage wiring.
- Inspect thermostat cable: Look for staples driven through the cable, rodent damage, or bare wires touching metal.
- Check float switch: If your Luxaire air handler has a condensate safety (float) switch, ensure the drain pan is not full and the switch is not tripped. Clear the drain if needed.
- Tighten low‑voltage connections: At the air handler and condenser, tighten R, C, Y, G, and other low‑voltage terminals.
- Transformer test (advanced): A technician can measure 24V output under load and replace the transformer if weak.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
24V Control Transformer