P2
Luxaire Inverter Module Overheat Protection

Luxaire ductless/variable‑speed AC shows P2; compressor speed is limited or unit shuts down.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked airflow over inverter heat sink, Failed inverter cooling fan (if equipped), High ambient temperature, Degraded thermal compound on module

How to Fix / Troubleshooting

Safety: Disconnect power before opening inverter compartments.

  • Clean electronics compartment: Remove dust and debris from around the Luxaire inverter heat sink and any small cooling fans using compressed air (low pressure) or a soft brush.
  • Verify fan operation: If a dedicated electronics fan is present, ensure it runs whenever the compressor is operating. Replace if seized or noisy.
  • Improve ventilation: Ensure the outdoor unit has adequate clearance and is not installed in a confined, unventilated space.
  • Technician service: If P2 persists, a technician may need to re‑apply thermal compound or replace the inverter module.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Inverter Module Cooling Fan
Check Price on Amazon