Luxaire
Mechanical Noise / Fan or Compressor Mount Failure
Luxaire air conditioner runs but makes loud banging or clanking noises from the outdoor unit.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose condenser fan blade, Bent fan blade hitting shroud, Failed compressor mounting springs, Debris inside condenser cabinet
How to Fix / Troubleshooting
Safety: Turn off power at the disconnect before opening the condenser.
- Inspect fan blade: Remove the top grille and visually inspect the Luxaire fan blade. Tighten the hub set screw on the motor shaft. Replace the blade if bent or cracked.
- Check for debris: Remove sticks, rocks, or other objects that may have fallen into the cabinet.
- Compressor mounts: If the noise is from the compressor base, inspect rubber mounts or springs. Broken mounts can allow the compressor to bang against the cabinet and should be replaced by a technician.
- Do not run with severe noise: Operating with mechanical interference can cause further damage. Leave the unit off until repaired.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Condenser Fan Blade
Check Price on Amazon
We may earn a commission from links on this page.