P2
Mitsubishi Electric
Inverter Module Overcurrent / Short Circuit Protection
Outdoor unit stops, P2 error, compressor may start then quickly stop
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Shorted compressor windings, Shorted IGBT module on inverter PCB, Wiring short between inverter and compressor, Mechanical compressor lock causing overcurrent
How to Fix / Troubleshooting
Safety first: High voltage and high current components are involved. Only trained technicians should perform these checks. Disconnect power at the main disconnect.
Steps:
- Visual inspection: Open the outdoor unit and inspect the inverter PCB and compressor terminals for burn marks, melted insulation, or a burnt smell.
- Check compressor wiring: Ensure the compressor harness is intact and not rubbing against sharp metal edges.
- Resistance tests (technician): A technician should measure compressor winding resistance and insulation resistance to ground. Abnormal readings indicate a failed compressor.
- Replace faulty parts: If the compressor is shorted, it must be replaced and the system evacuated and recharged. If the compressor is good but the inverter module is damaged, replace the inverter PCB.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Outdoor Inverter PCB or Compressor