F3
MrCool
Outdoor Coil Temperature Sensor (T3) Fault
Indoor unit shows F3; system may shut down or defrost improperly in heat mode.
Advertisements
Possible Causes
Open or shorted T3 sensor, Sensor not attached to outdoor coil, Damaged sensor wiring
How to Fix / Troubleshooting
Safety first: Turn off power at the outdoor disconnect.
Steps:
- Locate T3 sensor: The outdoor coil temperature sensor is clipped to the outdoor condenser coil tubing.
- Inspect sensor and wires: Check for broken wires, corrosion, or a sensor that has fallen off the coil.
- Reconnect or reclip: If the sensor is loose, reattach it firmly to the coil tube.
Repair: If the sensor appears damaged or F3 persists, replace the T3 outdoor coil sensor. This is a simple part but requires safe access to the outdoor unit.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Outdoor Coil Temperature Sensor (T3)
Check Price on Amazon