E5
Olimpia Splendid Compressor Overcurrent / Overload Protection Trip

E5 error; compressor does not start or stops shortly after starting

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Locked or mechanically tight compressor, Faulty compressor run capacitor (on portable/monobloc units), Shorted compressor windings, Defective inverter or power module on main PCB

How to Fix / Troubleshooting

Danger: High voltage present. Do not work on live circuits. If you are not experienced with electrical testing, call a professional.

  • Basic reset: Turn the unit off and unplug it for 10–15 minutes. Restore power and test. If E5 appears immediately, proceed with checks.
  • Check supply voltage: Ensure the outlet or dedicated circuit provides stable voltage within the range specified on the Olimpia Splendid rating plate. Low voltage can cause overcurrent trips.
  • Inspect wiring to compressor: With power off and covers removed, check the compressor terminal cover and wiring harness for burn marks, loose spade connectors, or melted insulation.
  • Test run capacitor (if equipped): On many Olimpia Splendid portable units, a run capacitor assists compressor start. Discharge the capacitor safely, then measure capacitance with a meter. Replace if more than ±10% out of rating.
  • Check for mechanical lock: A very hot, humming compressor that trips quickly may be seized. This requires compressor replacement, which must be done by an F-gas certified technician.
  • Inverter models: If your Olimpia Splendid unit uses an inverter compressor, E5 can indicate a power module fault. Visual inspection for burnt components is possible, but replacement of the inverter PCB should be left to a professional.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Compressor Run Capacitor
Check Price on Amazon

We may earn a commission from links on this page.