F1
Olimpia Splendid Indoor Ambient Temperature Sensor Error

F1 on display; unit may still run but with limited control accuracy

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed indoor ambient NTC sensor, Loose sensor connector on indoor PCB, Damaged sensor cable, Faulty PCB sensor circuit

How to Fix / Troubleshooting

Safety: Disconnect power before removing the front cover.

  • Access sensor: Remove the front panel and filter of the Olimpia Splendid indoor unit. The ambient sensor is often near the air intake grille.
  • Inspect sensor and wiring: Ensure the sensor is not broken or hanging loose. Check the cable for cuts or pinches.
  • Reseat connector: Follow the cable to the PCB and unplug/replug the connector to ensure good contact.
  • Test resistance: Use a multimeter to measure sensor resistance at room temperature. Replace the sensor if readings are open, shorted, or far from expected values.
  • PCB check: If a new sensor does not clear F1, the indoor PCB may be defective and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Indoor Ambient NTC Sensor