F5
Olimpia Splendid Defrost Sensor / Outdoor Coil Sensor Error

F5 displayed; unit may not heat or may stop in heating mode

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective defrost NTC sensor, Sensor detached from outdoor coil, Damaged sensor wiring, Faulty outdoor PCB sensor circuit

How to Fix / Troubleshooting

Safety: Turn off power at the breaker before opening the outdoor unit.

  • Locate defrost sensor: On Olimpia Splendid heat pump models, the defrost sensor is attached to the outdoor coil tubing.
  • Check attachment: Ensure the sensor is firmly clipped or strapped to the coil. Reattach if loose.
  • Inspect wiring: Look for cracked insulation or pulled wires, especially where they pass through metal openings.
  • Test sensor: Disconnect and measure resistance. Replace if readings are open, shorted, or inconsistent with temperature.
  • Replace sensor: Install a new "Defrost NTC sensor" and secure it in the same position.
  • PCB fault: If F5 persists with a known-good sensor, the outdoor PCB may require replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Defrost NTC Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements