H1
Olimpia Splendid
Defrost Mode Active / Defrost Protection Indication
H1 displayed during heating; outdoor unit may frost heavily; indoor unit may blow cool air
Advertisements
Possible Causes
Normal defrost operation in low ambient temperatures, Slightly dirty outdoor coil causing extended defrost, Weak outdoor fan airflow, Faulty defrost sensor if H1 persists abnormally
How to Fix / Troubleshooting
Note: On many Olimpia Splendid heat pump models, H1 is informational, indicating defrost mode, not a fault.
- Observe duration: If H1 appears briefly and then clears, this is normal defrost operation.
- Clean outdoor coil: If H1 remains for very long periods, clean the outdoor coil to improve defrost efficiency.
- Check outdoor fan: Ensure the fan is running properly; poor airflow can cause excessive frost.
- Sensor check: If H1 never clears or heating is very poor, have a technician test the defrost sensor and control logic.
Advertisements
Repair Difficulty
Very Easy
1/5
Advertisements