P2
Olimpia Splendid Low Temperature Protection / Anti-Freeze Protection

P2 displayed; unit may run in fan-only mode; cooling disabled

Advertisements

Possible Causes

Evaporator coil icing due to low ambient temperature, Very low fan speed or blocked airflow, Low refrigerant charge, Faulty evaporator sensor

How to Fix / Troubleshooting

Note: P2 often indicates the unit is protecting itself from freezing.

  • Check room and set temperature: Ensure the set temperature is not too low relative to room temperature, especially in cool environments.
  • Clean filter and coil: Dirty filters and coils on Olimpia Splendid units can cause icing. Clean them thoroughly.
  • Inspect fan speed: Make sure the indoor fan is running at normal speed. Address any fan issues.
  • Defrost the coil: Turn the unit off and allow any ice on the evaporator to melt completely before restarting.
  • Persistent P2: If the error recurs frequently, have a technician check refrigerant charge and the evaporator sensor.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Evaporator NTC Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements