Olimpia Splendid Compressor Start Failure

Unit powers on but compressor never starts; only fan runs

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed compressor, Faulty start/run capacitor (non-inverter models), Defective relay or triac on PCB, Low ambient temperature lockout

How to Fix / Troubleshooting

Danger: High voltage and high current circuits are involved. Exercise caution.

  • Check mode and temperature: Ensure the unit is in COOL mode and the set temperature is low enough to call for cooling.
  • Listen for compressor: A brief click without compressor hum may indicate a control issue; a loud hum then stop suggests a mechanical or capacitor problem.
  • Inspect capacitor (if accessible): On some Olimpia Splendid portable units, the compressor capacitor is accessible behind a side panel. Discharge and test it; replace if out of spec.
  • Ambient lockout: Some models prevent compressor operation below a certain temperature. Check the manual for operating limits.
  • Technician required: If the compressor is receiving correct voltage but does not start, it or the PCB is likely faulty and needs professional diagnosis.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Compressor Run Capacitor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements