F90
Panasonic Inverter Compressor Start-Up Failure

Unit stops with F90; compressor may not start or may stop quickly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty inverter compressor, Defective outdoor inverter PCB, Low supply voltage, Loose power connections

How to Fix / Troubleshooting

Warning: High-voltage inverter circuits are dangerous. Limit checks to visual inspection and basic electrical safety.

Steps:

  • 1. Check supply voltage: Ensure the AC supply matches the unit's rated voltage and is stable.
  • 2. Inspect power terminals: With power OFF, tighten L/N (and L1/L2/L3 for 3-phase) terminals at the outdoor unit.
  • 3. Visual PCB check: Look for burnt or cracked components on the inverter PCB.

If F90 persists, a technician must test the compressor and inverter PCB and replace the defective part.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Outdoor Inverter PCB
Check Price on Amazon