H33
Panasonic
Outdoor Airflow / Fan System Abnormality
H33 displayed; unit may not start or may shut down quickly.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked outdoor coil, Faulty outdoor fan motor, Fan blade obstruction, Faulty outdoor PCB fan drive
How to Fix / Troubleshooting
Safety first: Turn off power at the breaker and outdoor isolator.
Steps:
- 1. Clear obstructions: Remove leaves, plastic bags, and debris from the outdoor grille and coil.
- 2. Clean coil surface: Gently brush dirt from the coil fins. For heavy dirt, use a low-pressure water spray from inside out, avoiding the PCB.
- 3. Check fan blade: Ensure the blade is not cracked or rubbing on the shroud. Spin by hand to confirm free movement.
- 4. Inspect fan motor wiring: Confirm connectors are secure and not burnt.
If the fan does not run when the unit is calling for cooling/heating, the fan motor or outdoor PCB likely needs replacement by a technician.