Short Cycling / Improper Capacity or Control
Unit frequently turns on and off (short cycling) without reaching set temperature.
Advertisements
Possible Causes
Oversized unit for room size, Dirty filters or coils, Thermistor sensing return air incorrectly, Incorrect thermostat placement (for ducted systems)
How to Fix / Troubleshooting
Steps:
- 1. Clean filters and coils: Ensure good airflow to prevent rapid temperature swings at the sensor.
- 2. Check set temperature and mode: Avoid setting the temperature extremely low/high; use moderate settings.
- 3. Inspect room sensor location: For ducted Panasonic units with remote sensors, ensure the sensor is not near supply vents or heat sources.
If short cycling persists and the unit is significantly oversized, there is no simple fix; consult an HVAC professional about zoning or capacity adjustment options.