Possible Causes

Open or shorted room temperature sensor (NTC), Loose sensor connector on indoor PCB, Damaged sensor wiring harness, Indoor PCB sensor input failure

How to Fix / Troubleshooting

Safety first: Turn off power to the indoor unit before accessing the control board or sensors.

Steps to try:

  • Locate the room sensor: On Pioneer wall-mount units, the room sensor is usually clipped near the air intake or behind the front grille, connected by two small wires to the PCB.
  • Check connection: Gently unplug and replug the sensor connector on the indoor PCB to ensure a solid connection.
  • Inspect sensor: Look for damage to the sensor body or pinched wires. If the sensor is broken or corroded, it should be replaced with a Pioneer-compatible NTC sensor.
  • Reset power: After reseating the connector, restore power and test operation. If F1 returns, the sensor or PCB is likely defective.

When to call a pro: If replacing the sensor does not clear F1, the indoor PCB sensor circuit may need replacement.