H6
Rheem Indoor Fan or Indoor Unit Communication Fault

Rheem multi‑zone system displays H6 and one or more indoor units do not respond or show communication errors.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed indoor fan motor on one zone, Open communication wiring to a specific indoor unit, Incorrect indoor address or wiring, Faulty indoor PCB

How to Fix / Troubleshooting

Safety first: Turn off power to the entire multi‑zone system.

  • Identify affected zone: Determine which indoor unit(s) are not operating or showing error.
  • Check fan motor: On the affected unit, inspect and test the indoor fan motor as for E8 faults.
  • Verify wiring: Confirm that the communication and power wiring from the outdoor unit to each indoor unit is correctly landed and secure.
  • Swap test (advanced): A technician may temporarily swap indoor PCBs between zones to see if the fault follows the board.

Warning: Multi‑zone communication issues can be complex; improper wiring changes can affect all zones.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Rheem Indoor Fan Motor / Indoor Unit Control Board
Check Price on Amazon