Rheem
Thermostat Power or Communication Issue
Rheem air conditioner thermostat shows error or blank screen, but equipment has power.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blown low-voltage fuse on air handler board, Broken thermostat cable, Incorrect thermostat wiring, Incompatible thermostat with Rheem communicating system
How to Fix / Troubleshooting
Safety first: Turn off power to the air handler before working on low-voltage wiring.
- Check control fuse: Inspect and replace the low-voltage fuse on the Rheem air handler control board if blown.
- Verify wiring: Remove the thermostat and check that R, C, Y, G, and W (if used) are correctly connected and secure.
- Test cable: If possible, temporarily connect a short piece of thermostat wire directly at the air handler to a test thermostat to rule out cable damage.
- Compatibility: For Rheem communicating systems, ensure you are using a compatible Rheem thermostat or controller.
Warning: Shorting thermostat wires can blow the control fuse or damage the board.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Rheem Air Handler Control Board Fuse / Thermostat / Thermostat Cable
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements