E8
Ruud
Compressor Discharge Temperature High
Ruud air conditioner displays E8 and may shut down or limit operation during very hot weather.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Dirty condenser coil, Low refrigerant charge causing high superheat, Restricted liquid line filter-drier, Failed discharge temperature sensor
How to Fix / Troubleshooting
Safety first: Disconnect power at the outdoor disconnect before cleaning or opening panels. Refrigerant diagnostics must be done by a licensed technician.
- Step 1 – Clean condenser coil: Remove debris and rinse the coil thoroughly from inside out with a garden hose. Allow to dry and restore power.
- Step 2 – Check outdoor fan operation: Confirm the Ruud condenser fan starts promptly and runs at full speed. A weak or non-running fan will cause high discharge temperatures.
- Step 3 – Inspect discharge sensor: Locate the discharge line thermistor near the compressor outlet. Ensure it is firmly attached and insulated as designed. Check for damaged wires.
- Step 4 – Technician checks: If E8 recurs, a technician should check refrigerant charge, superheat/subcooling, and the filter-drier for restriction. They may replace the discharge sensor if readings are abnormal.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Compressor Discharge Thermistor