E9
Ruud EEPROM / Control Board Memory Error

Ruud air conditioner shows E9; unit may not start or may shut down unexpectedly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Corrupted control board firmware, Power surge damage, Failed control board EEPROM, Loose board connectors

How to Fix / Troubleshooting

Safety first: Turn off all power to the indoor and outdoor units before touching control boards.

  • Step 1 – Power reset: Turn off the indoor air handler/furnace breaker and outdoor disconnect. Wait at least 5 minutes, then restore power. This can clear transient memory faults.
  • Step 2 – Inspect board connections: Remove the control panel cover and gently press on all multi-pin connectors to ensure they are fully seated. Look for corrosion or bent pins.
  • Step 3 – Surge damage check: Look for burn marks, swollen components, or a burnt smell on the Ruud control board. If present, the board must be replaced.
  • Step 4 – Firmware/board replacement: If E9 persists after a power reset and connections are good, the control board’s EEPROM is likely corrupted. Replacement of the control board with the correct Ruud part number is required and should be done by a technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Outdoor Control Board
Check Price on Amazon

We may earn a commission from links on this page.