F5
Ruud Blower Overcurrent / Motor Protection Trip

Ruud air conditioner indoor unit displays F5; blower may not start or may shut off unexpectedly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Seized blower wheel or bearings, Obstructed ductwork causing high static pressure, Shorted blower motor windings, Incorrect motor tap or programming

How to Fix / Troubleshooting

Safety first: Turn off power at the breaker. Blower assemblies are heavy; support them properly when removing.

  • Step 1 – Inspect blower wheel: Remove blower access panel and check for debris, insulation, or objects lodged in the wheel. Clean thoroughly.
  • Step 2 – Check wheel and motor bearings: Spin the wheel by hand. If it grinds or stops quickly, bearings may be failing. Replace the blower motor or assembly as needed.
  • Step 3 – Verify duct and filter condition: Ensure filters are clean and ducts/registers are not blocked. Excessive static pressure can overload the motor.
  • Step 4 – Motor wiring/programming: For multi-speed or ECM motors, verify the correct speed tap or program is selected per Ruud installation instructions. Incorrect settings can cause overcurrent.
  • Step 5 – Technician testing: If F5 persists, a technician should measure motor amp draw and compare to nameplate rating, then replace the motor if overloaded or shorted.