L1
Ruud Line Voltage Low / Brownout Protection

Ruud air conditioner control board indicates L1; unit may not start or may trip breaker.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Low supply voltage from utility, Undersized wiring or long run causing voltage drop, Loose line voltage connections, Failing contactor or high-resistance connections

How to Fix / Troubleshooting

Safety first: High voltage is present. Turn off the breaker and disconnect before tightening connections. Voltage measurements should be done by qualified personnel.

  • Step 1 – Check other appliances: If lights dim or other appliances struggle, there may be a general low-voltage issue. Contact your utility provider.
  • Step 2 – Inspect connections: With power off, inspect the Ruud condenser’s line lugs, disconnect, and breaker connections for looseness or overheating. Tighten to spec.
  • Step 3 – Wire size and length: Ensure the installed wire gauge matches Ruud’s installation manual for the unit’s ampacity and distance. Undersized wire can cause voltage drop.
  • Step 4 – Technician testing: A technician should measure voltage under load at the unit. If consistently below manufacturer minimum, corrective electrical work is required.