Mechanical Vibration or Loose Components
Indoor unit makes loud rattling or buzzing noises during operation.
Advertisements
Possible Causes
Loose indoor fan blower, Loose mounting bracket, Foreign object in blower, Vibrating copper pipes touching chassis
How to Fix / Troubleshooting
Safety first: Turn off power before touching moving parts.
- Step 1 – Check front panel: Ensure the Samsung indoor unit front cover is fully closed and latched on both sides.
- Step 2 – Inspect blower area: Remove filters and look inside for loose plastic pieces, cable ties, or debris contacting the blower wheel.
- Step 3 – Check mounting bracket: Gently push on the indoor unit. Excessive movement indicates loose wall bracket screws; tighten them.
- Step 4 – Inspect piping: Where refrigerant pipes exit the indoor unit, ensure they are not touching the wall or metal edges. Add foam insulation or padding if necessary.
- Step 5 – Test: Restore power and run the fan. If noise persists, the blower wheel or motor may be damaged and require replacement.