E9
Sharp
Indoor Coil Overheat / Protection Error
Unit stops and displays E9; sometimes associated with water leakage or abnormal coil temperature.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Severely blocked indoor coil, Indoor fan not running properly, Refrigerant flow restriction, Faulty coil thermistor reading too high
How to Fix / Troubleshooting
Safety first: Turn off power at the breaker before cleaning or inspecting internal parts.
- Clean indoor coil: Remove filters and inspect the coil. If heavily clogged with dust, use a soft brush and vacuum to clean. For deeper cleaning, use a coil-safe cleaner following the product instructions.
- Verify fan operation: Ensure the indoor fan runs at all speeds. If it is slow or intermittent, check for obstructions and consider replacing the fan motor.
- Thermistor position: Confirm the coil sensor is properly clipped to the coil. A sensor hanging in free air can misread and trigger E9.
- Refrigerant / system issues: If airflow is good and the sensor is correct but E9 persists, there may be a refrigerant or expansion valve problem causing abnormal coil temperatures. This must be diagnosed by a professional with gauges and Sharp service data.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Indoor Evaporator Coil Thermistor
Check Price on Amazon