F4
Sharp
High Discharge Temperature / Overheat Protection
Unit stops and F4 is displayed; often associated with high outdoor temperature or dirty condenser.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Dirty or blocked outdoor condenser coil, Failed outdoor fan motor, Overcharged refrigerant, Restricted airflow around outdoor unit
How to Fix / Troubleshooting
Safety first: Turn off the outdoor unit breaker before cleaning or servicing.
- Clear surroundings: Ensure at least the manufacturer-recommended clearance around the outdoor unit (typically 30–50 cm sides, more above). Remove any obstructions.
- Clean condenser coil: Use a garden hose with low pressure to rinse dirt from the coil fins from inside out. Avoid high pressure that can bend fins.
- Check outdoor fan: Confirm the fan runs at full speed when the unit is cooling. If it is slow, intermittent, or not running, replace the outdoor fan motor.
- Thermistor check: Verify the discharge pipe sensor is properly attached and insulated. Replace if faulty.
- Refrigerant charge: If F4 persists with clean coil and good airflow, a technician should check for overcharge or system restrictions using gauges and Sharp service data.