P3
Sharp
Low Ambient Temperature Protection / Anti-freeze
Portable Sharp AC: unit stops cooling; P3 displayed, often in low ambient conditions.
Advertisements
Possible Causes
Room temperature below operating range, Evaporator coil temperature too low, Faulty evaporator thermistor, Blocked air intake
How to Fix / Troubleshooting
Safety first: Unplug the unit before cleaning filters or moving it.
- Check room temperature: Ensure the room is within the unit’s specified operating range (often above ~18°C for cooling).
- Clean filters and vents: Remove and clean filters. Ensure intake and exhaust vents are not blocked.
- Allow coil to defrost: If the unit has been running in a very cool room, let it sit off for 30–60 minutes, then restart.
- Sensor check: If P3 appears even in warm conditions, the evaporator thermistor may be faulty and should be replaced by a service technician.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Evaporator Temperature Thermistor
Check Price on Amazon