Sharp
Short Cycling / Improper Capacity Control
Unit frequently turns on and off (short cycling) without reaching set temperature.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Oversized unit for room size, Thermistor located in direct airflow or near heat source, Dirty filters causing incorrect temperature sensing, Faulty room temperature sensor
How to Fix / Troubleshooting
Safety first: Turn off power before accessing sensors or PCB.
- Check sensor location: Ensure the room temperature sensor is not directly in the cold air stream or near heat sources (lamps, electronics). Reposition if possible according to Sharp guidelines.
- Clean filters and coil: Dirty filters can cause uneven temperature distribution and false readings.
- Fan speed setting: Use a lower fan speed to reduce drafts directly on the sensor.
- Sensor replacement: If the unit still short cycles, replace the room temperature thermistor.
- Capacity mismatch: If the unit is significantly oversized, consider using a lower setpoint range or consulting an HVAC professional about proper sizing.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Indoor Room Temperature Thermistor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements