E6
SMEG Communication Error Between Indoor and Outdoor Units

Indoor unit shows E6 and does not respond properly to remote commands

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose communication cable between indoor and outdoor units, Reversed polarity on L/N or communication terminals, Damaged communication cable, Faulty indoor or outdoor main PCB

How to Fix / Troubleshooting

Safety first: Turn off power at the main isolator before accessing terminal blocks.

  • Verify wiring connections: Open the indoor and outdoor electrical covers. Confirm that the communication terminals (often labeled S, 1, 2, 3, etc.) are wired identically at both ends and firmly tightened.
  • Check polarity: Ensure Live (L), Neutral (N), and Earth are correctly connected and not swapped with communication terminals.
  • Inspect cable condition: Look for cuts, crushed sections, or water ingress in the interconnecting cable. Replace if damaged.
  • Power cycle: After correcting wiring, power off for 5 minutes, then restore power and test.

If E6 persists with correct wiring and a good cable, either the indoor or outdoor PCB may be defective and should be tested/replaced by a technician.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Interconnecting Communication Cable
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements